The following should be considered:
1. If the leak seems to originate at one or both pump connections (unions), call the dealer. The Dealer will need to check the tightness of pump unions.
2. If occasional leaks seem to originate at the bath overflow, tighten down the overflow to the tub.
3. If the leak seems to originate at the pump seal, pipe-to-jet body or jet-body-to-bath connection, call the dealer.
|
Your air switch is connected to the motor using clear tubing. Ensure that the tubing is connected to both the air switch and the motor.
If the motor still will not turn on call 1-800-999-1459 for customer service.
|
You can simply turn off the system by either unplugging, or shutting off power at the housebreaker panel. Power back up, the control will
run a self-diagnostic check. If there is still a problem reference the Swirl-way Owner's Manual for troubleshooting tips or call customer service at 1-800-999-1459.
|
Check for loose wiring or connections. Check for low voltage at motor (frequently caused by undersized wiring). Check for air leak in suction line causing a
rumbling in pump. Improper mounting or vibration may cause pump to become loose causing leaks or noise.
|
Check for obstructions in the suction and discharge line. Check voltage to make sure pump is up to speed. Make sure all Magna-Swirl I jets are turned counterclockwise
to fully open.
|